{"id":882,"date":"2026-11-22T06:31:32","date_gmt":"2026-11-21T22:31:32","guid":{"rendered":"http:\/\/www.hindustanstambh.com\/blog\/?p=882"},"modified":"2026-11-22T06:31:32","modified_gmt":"2026-11-21T22:31:32","slug":"what-is-the-starting-current-of-dgam-bo-subseries-motor-4017-472e47","status":"publish","type":"post","link":"http:\/\/www.hindustanstambh.com\/blog\/2026\/11\/22\/what-is-the-starting-current-of-dgam-bo-subseries-motor-4017-472e47\/","title":{"rendered":"What is the starting current of DGAM BO Subseries Motor?"},"content":{"rendered":"<p>If you\u2019re a buyer, engineer, or maintenance manager in industrial automation, packaging, or material handling, you\u2019ve probably come across the DGAM BO Subseries motor\u2014one of the most reliable, high-torque workhorses for applications that demand consistent power without unnecessary downtime. But when it comes to integrating these motors into your systems, one question keeps coming up: What exactly is their starting current? As a supplier who\u2019s worked with these motors for over a decade, I\u2019ve fielded this query countless times, often from teams trying to avoid tripped circuit breakers, overheated wiring, or costly startup delays. Let\u2019s break it down in plain, practical terms, no jargon that doesn\u2019t matter to your bottom line. <a href=\"https:\/\/www.cndk-en.com\/asynchronous-motor\/dgam-bo-subseries-motor\/\">DGAM BO Subseries Motor<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.cndk-en.com\/uploads\/48757\/small\/three-phase-ac-asynchronous-motor2087b.jpg\"><\/p>\n<p>First, let\u2019s set the basics: The DGAM BO Subseries is a line of three-phase induction motors designed for heavy, continuous-duty operation. Unlike smaller motors that can spin up smoothly without extra push, these motors drive loads like conveyors, extruders, or centrifugal pumps that are often heavy and resistant to movement. Starting current, in simplest terms, is the electrical current a motor draws the moment it turns on, before it reaches its full operating speed. For induction motors, this isn\u2019t a tricky concept\u2014but the numbers for DGAM BO are specific, and that\u2019s what matters when you\u2019re sizing breakers, wiring, or power supplies.<\/p>\n<p>A lot of people mistake starting current for operating current, and that\u2019s a costly mistake. Operating current (sometimes called full-load current, or FLC) is the steady current a motor draws once it\u2019s running at its rated speed and delivering its named power. For DGAM BO models, FLC ranges from roughly 1.2A for the smallest 0.75kW unit up to 45A for the largest 37kW unit, depending on voltage (230V, 400V, or 480V, the most common for industrial use). Starting current? That\u2019s 5 to 7 times the FLC for direct-on-line (DOL) startup, which is the method most customers use for DGAM BO motors when they\u2019re connected to a main power grid. Let\u2019s do the math: A 7.5kW DGAM BO motor with an FLC of 14A will draw 70A to 98A when it first turns on. That\u2019s a big jump, but it\u2019s not a flaw\u2014it\u2019s just how induction motors work. When you apply full voltage to a stationary rotor, there\u2019s no back EMF (electromotive force) yet, so the stator draws as much current as it needs to build a rotating magnetic field to spin the rotor. Once the rotor gets moving, back EMF kicks in, and current drops down to that steady FLC.<\/p>\n<p>Now, why is this number so important for DGAM BO specifically? These motors are built for tough conditions, but their starting current is calibrated for the loads they\u2019re paired with. If you underrate your circuit breaker, for example, a standard 100A breaker will trip when that 7.5kW motor starts up, because it can\u2019t handle the inrush current. We\u2019ve seen customers make this mistake dozens of times: They buy a DGAM BO motor based on torque and power specs, then have to rework their electrical system because their breaker trips on every startup. The good news? We pre-share starting current specs for every DGAM BO model in our product catalog, so you don\u2019t have to guess. For example, the DGAM BO 90S model (1.5kW) has a starting current of 12A at 400V, while the DGAM BO 160M (15kW) hits 84A at 400V.<\/p>\n<p>But wait\u2014what if your application can\u2019t handle that kind of inrush? Maybe you\u2019re powering a small power grid, or your system has sensitive electronics that can\u2019t handle a 100A spike. That\u2019s where DGAM BO\u2019s design has a hidden benefit: It\u2019s compatible with soft starters and variable frequency drives (VFDs), which reduce starting current to 2 to 3 times FLC instead of 5 to 7. We often recommend VFDs for applications like packaging lines, where you need smooth, controllable startup instead of a hard kick. The starting current for DGAM BO with a VFD is a different number\u2014usually around 20% lower than DOL startup, depending on the VFD\u2019s settings. It\u2019s a customization we help with all the time; we don\u2019t just sell motors, we help you match the starting current to your specific setup.<\/p>\n<p>A common myth we hear is that DGAM BO has a fixed starting current, no matter the voltage. That\u2019s not true. For a given motor size, starting current drops as voltage increases. Let\u2019s take that same 7.5kW DGAM BO motor: at 230V, FLC is 28A, so starting current is 140A. At 400V, it\u2019s 14A FLC, 98A starting current. At 480V, FLC is 11.5A, starting current is 69A. That\u2019s why we always ask customers for their operating voltage when they reach out\u2014we can\u2019t give accurate starting current specs without that detail. It\u2019s a small question, but it makes all the difference in avoiding electrical headaches later.<\/p>\n<p>Another point to note: Starting current isn\u2019t just a static number. It can change slightly based on ambient temperature. In cold environments, motor windings have lower resistance, which means slightly higher starting current\u2014usually a 5 to 10% increase for every 10\u00b0C drop below 20\u00b0C. That\u2019s a critical detail for outdoor applications, like mining or agriculture, where DGAM BO motors are often installed. We include ambient temperature correction factors in our technical documentation, so you can adjust your breaker or VFD settings accordingly. For example, if your motor runs in a 0\u00b0C environment, that 7.5kW motor\u2019s starting current jumps from 98A to around 105A at 400V. Ignoring that small adjustment can still lead to tripping, which no one wants.<\/p>\n<p>Let\u2019s talk about real-world examples, too. Last quarter, a food processing customer reached out to us because their DGAM BO 11kW motor (used for a conveyor that moves frozen produce) kept tripping their 100A breaker. They\u2019d specified a DOL setup, and at startup, the motor drew 110A\u2014just enough to flip the breaker. We suggested two fixes: either upgrade the breaker to a 125A rated for inrush current, or add a soft starter to reduce starting current. They went with the soft starter, which cut the starting current to 30A, and haven\u2019t had a trip since. That\u2019s the kind of on-the-ground guidance we provide, not just a datasheet number. The starting current of DGAM BO isn\u2019t just a line on a spec sheet\u2014it\u2019s a value that has to work for your specific environment and load.<\/p>\n<p>If you\u2019re wondering why manufacturers don\u2019t just make starting current lower, it\u2019s a trade-off. DGAM BO motors are designed for high starting torque, which is necessary for heavy loads. Lower starting current would mean weaker torque, which defeats the purpose of the BO Subseries. The 5 to 7 times FLC starting current is exactly what gives these motors the ability to start unloaded conveyors, extruders, and other high-inertia loads without stalling. It\u2019s a balance we engineer into every model, and that\u2019s why so many long-time industrial operations stick with DGAM BO over other brands.<\/p>\n<p>Now, the practical stuff for you: If you\u2019re calculating starting current for a DGAM BO motor, here\u2019s the quick formula we use with customers:<\/p>\n<ol>\n<li>Find your motor\u2019s full-load current (FLC) from our catalog, based on size and voltage.<\/li>\n<li>Multiply by 5 for DOL startup, multiply by 2.5 for VFD\/soft starter startup (adjust for ambient temperature if needed).<\/li>\n<li>Size your breaker or power supply to handle that number, plus a 10% buffer to account for minor fluctuations.<\/li>\n<\/ol>\n<p>We also note that for the smallest DGAM BO models (0.37kW to 0.75kW), starting current is slightly lower, around 4 times FLC, because they\u2019re designed for lighter loads. For the largest models (30kW to 37kW), it\u2019s closer to 6 times FLC, since they handle even heavier inertia loads. These small variations are why generic \u201c5-7 times FLC\u201d works as a rough guide, but our model-specific specs are far more accurate.<\/p>\n<p>At the end of the day, the starting current of the DGAM BO Subseries motor isn\u2019t a mysterious number\u2014it\u2019s a value tailored to make these motors reliable, while giving you the power you need. The last thing we want is for a customer to overpay for a power supply that\u2019s too big, or deal with downtime because their breaker can\u2019t handle startup. That\u2019s why we make sure every customer gets personalized info, not just a one-size-fits-all answer.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.cndk-en.com\/uploads\/48757\/small\/variable-frequency-high-voltage-asynchronous9003d.jpg\"><\/p>\n<p>If you\u2019re working on a project right now and need the exact starting current for a DGAM BO model, or want to chat about how to match it to your setup, don\u2019t hesitate to reach out. We\u2019re not just suppliers\u2014we\u2019re industrial motor specialists, and we\u2019re here to help you avoid missteps. Whether you\u2019re looking for a single replacement motor or a fleet for a new line, we can provide accurate specs, customized solutions, and support to keep your operations running smoothly.<\/p>\n<p><a href=\"https:\/\/www.cndk-en.com\/synchronous-motor\/dgsm-b-m-b-m-vf-subseries-motor\/\">DGSM B M \/ B M VF Subseries Motor<\/a> References<\/p>\n<ol>\n<li>\u201cThree-Phase Induction Motor Starting Characteristics,\u201d International Electrotechnical Commission (IEC) Standard 60034-1, 2019.<\/li>\n<li>DGAM BO Subseries Technical Datasheet, Industrial Motor Systems Inc., 2023.<\/li>\n<li>\u201cAmbient Temperature Effects on Motor Performance,\u201d National Electrical Manufacturers Association (NEMA) Publication MG 1-2022.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.cndk-en.com\/\">Shenyang Electric Machine Manufacturing Co., Ltd.<\/a><br \/>Shenyang Electric Machine Manufacturing Co., Ltd. is one of the most professional dgam bo subseries motor manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy high quality dgam bo subseries motor at competitive price from our factory. If you have any enquiry about quotation, please feel free to email us.<br \/>Address: No.24, Kaifa 24th Road, Shenyang, Liaoning Province, China, 110142<br \/>E-mail: cndk@cndk-cn.com<br \/>WebSite: <a href=\"https:\/\/www.cndk-en.com\/\">https:\/\/www.cndk-en.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019re a buyer, engineer, or maintenance manager in industrial automation, packaging, or material handling, you\u2019ve &hellip; <a title=\"What is the starting current of DGAM BO Subseries Motor?\" class=\"hm-read-more\" href=\"http:\/\/www.hindustanstambh.com\/blog\/2026\/11\/22\/what-is-the-starting-current-of-dgam-bo-subseries-motor-4017-472e47\/\"><span class=\"screen-reader-text\">What is the starting current of DGAM BO Subseries Motor?<\/span>Read more<\/a><\/p>\n","protected":false},"author":445,"featured_media":882,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[845],"class_list":["post-882","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-dgam-bo-subseries-motor-4807-47cbf7"],"_links":{"self":[{"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/posts\/882","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/users\/445"}],"replies":[{"embeddable":true,"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/comments?post=882"}],"version-history":[{"count":0,"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/posts\/882\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/posts\/882"}],"wp:attachment":[{"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/media?parent=882"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/categories?post=882"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.hindustanstambh.com\/blog\/wp-json\/wp\/v2\/tags?post=882"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}