If you’re a buyer, engineer, or maintenance manager in industrial automation, packaging, or material handling, you’ve probably come across the DGAM BO Subseries motor—one of the most reliable, high-torque workhorses for applications that demand consistent power without unnecessary downtime. But when it comes to integrating these motors into your systems, one question keeps coming up: What exactly is their starting current? As a supplier who’s worked with these motors for over a decade, I’ve fielded this query countless times, often from teams trying to avoid tripped circuit breakers, overheated wiring, or costly startup delays. Let’s break it down in plain, practical terms, no jargon that doesn’t matter to your bottom line. DGAM BO Subseries Motor

First, let’s set the basics: The DGAM BO Subseries is a line of three-phase induction motors designed for heavy, continuous-duty operation. Unlike smaller motors that can spin up smoothly without extra push, these motors drive loads like conveyors, extruders, or centrifugal pumps that are often heavy and resistant to movement. Starting current, in simplest terms, is the electrical current a motor draws the moment it turns on, before it reaches its full operating speed. For induction motors, this isn’t a tricky concept—but the numbers for DGAM BO are specific, and that’s what matters when you’re sizing breakers, wiring, or power supplies.
A lot of people mistake starting current for operating current, and that’s a costly mistake. Operating current (sometimes called full-load current, or FLC) is the steady current a motor draws once it’s running at its rated speed and delivering its named power. For DGAM BO models, FLC ranges from roughly 1.2A for the smallest 0.75kW unit up to 45A for the largest 37kW unit, depending on voltage (230V, 400V, or 480V, the most common for industrial use). Starting current? That’s 5 to 7 times the FLC for direct-on-line (DOL) startup, which is the method most customers use for DGAM BO motors when they’re connected to a main power grid. Let’s do the math: A 7.5kW DGAM BO motor with an FLC of 14A will draw 70A to 98A when it first turns on. That’s a big jump, but it’s not a flaw—it’s just how induction motors work. When you apply full voltage to a stationary rotor, there’s no back EMF (electromotive force) yet, so the stator draws as much current as it needs to build a rotating magnetic field to spin the rotor. Once the rotor gets moving, back EMF kicks in, and current drops down to that steady FLC.
Now, why is this number so important for DGAM BO specifically? These motors are built for tough conditions, but their starting current is calibrated for the loads they’re paired with. If you underrate your circuit breaker, for example, a standard 100A breaker will trip when that 7.5kW motor starts up, because it can’t handle the inrush current. We’ve seen customers make this mistake dozens of times: They buy a DGAM BO motor based on torque and power specs, then have to rework their electrical system because their breaker trips on every startup. The good news? We pre-share starting current specs for every DGAM BO model in our product catalog, so you don’t have to guess. For example, the DGAM BO 90S model (1.5kW) has a starting current of 12A at 400V, while the DGAM BO 160M (15kW) hits 84A at 400V.
But wait—what if your application can’t handle that kind of inrush? Maybe you’re powering a small power grid, or your system has sensitive electronics that can’t handle a 100A spike. That’s where DGAM BO’s design has a hidden benefit: It’s compatible with soft starters and variable frequency drives (VFDs), which reduce starting current to 2 to 3 times FLC instead of 5 to 7. We often recommend VFDs for applications like packaging lines, where you need smooth, controllable startup instead of a hard kick. The starting current for DGAM BO with a VFD is a different number—usually around 20% lower than DOL startup, depending on the VFD’s settings. It’s a customization we help with all the time; we don’t just sell motors, we help you match the starting current to your specific setup.
A common myth we hear is that DGAM BO has a fixed starting current, no matter the voltage. That’s not true. For a given motor size, starting current drops as voltage increases. Let’s take that same 7.5kW DGAM BO motor: at 230V, FLC is 28A, so starting current is 140A. At 400V, it’s 14A FLC, 98A starting current. At 480V, FLC is 11.5A, starting current is 69A. That’s why we always ask customers for their operating voltage when they reach out—we can’t give accurate starting current specs without that detail. It’s a small question, but it makes all the difference in avoiding electrical headaches later.
Another point to note: Starting current isn’t just a static number. It can change slightly based on ambient temperature. In cold environments, motor windings have lower resistance, which means slightly higher starting current—usually a 5 to 10% increase for every 10°C drop below 20°C. That’s a critical detail for outdoor applications, like mining or agriculture, where DGAM BO motors are often installed. We include ambient temperature correction factors in our technical documentation, so you can adjust your breaker or VFD settings accordingly. For example, if your motor runs in a 0°C environment, that 7.5kW motor’s starting current jumps from 98A to around 105A at 400V. Ignoring that small adjustment can still lead to tripping, which no one wants.
Let’s talk about real-world examples, too. Last quarter, a food processing customer reached out to us because their DGAM BO 11kW motor (used for a conveyor that moves frozen produce) kept tripping their 100A breaker. They’d specified a DOL setup, and at startup, the motor drew 110A—just enough to flip the breaker. We suggested two fixes: either upgrade the breaker to a 125A rated for inrush current, or add a soft starter to reduce starting current. They went with the soft starter, which cut the starting current to 30A, and haven’t had a trip since. That’s the kind of on-the-ground guidance we provide, not just a datasheet number. The starting current of DGAM BO isn’t just a line on a spec sheet—it’s a value that has to work for your specific environment and load.
If you’re wondering why manufacturers don’t just make starting current lower, it’s a trade-off. DGAM BO motors are designed for high starting torque, which is necessary for heavy loads. Lower starting current would mean weaker torque, which defeats the purpose of the BO Subseries. The 5 to 7 times FLC starting current is exactly what gives these motors the ability to start unloaded conveyors, extruders, and other high-inertia loads without stalling. It’s a balance we engineer into every model, and that’s why so many long-time industrial operations stick with DGAM BO over other brands.
Now, the practical stuff for you: If you’re calculating starting current for a DGAM BO motor, here’s the quick formula we use with customers:
- Find your motor’s full-load current (FLC) from our catalog, based on size and voltage.
- Multiply by 5 for DOL startup, multiply by 2.5 for VFD/soft starter startup (adjust for ambient temperature if needed).
- Size your breaker or power supply to handle that number, plus a 10% buffer to account for minor fluctuations.
We also note that for the smallest DGAM BO models (0.37kW to 0.75kW), starting current is slightly lower, around 4 times FLC, because they’re designed for lighter loads. For the largest models (30kW to 37kW), it’s closer to 6 times FLC, since they handle even heavier inertia loads. These small variations are why generic “5-7 times FLC” works as a rough guide, but our model-specific specs are far more accurate.
At the end of the day, the starting current of the DGAM BO Subseries motor isn’t a mysterious number—it’s a value tailored to make these motors reliable, while giving you the power you need. The last thing we want is for a customer to overpay for a power supply that’s too big, or deal with downtime because their breaker can’t handle startup. That’s why we make sure every customer gets personalized info, not just a one-size-fits-all answer.

If you’re working on a project right now and need the exact starting current for a DGAM BO model, or want to chat about how to match it to your setup, don’t hesitate to reach out. We’re not just suppliers—we’re industrial motor specialists, and we’re here to help you avoid missteps. Whether you’re looking for a single replacement motor or a fleet for a new line, we can provide accurate specs, customized solutions, and support to keep your operations running smoothly.
DGSM B M / B M VF Subseries Motor References
- “Three-Phase Induction Motor Starting Characteristics,” International Electrotechnical Commission (IEC) Standard 60034-1, 2019.
- DGAM BO Subseries Technical Datasheet, Industrial Motor Systems Inc., 2023.
- “Ambient Temperature Effects on Motor Performance,” National Electrical Manufacturers Association (NEMA) Publication MG 1-2022.
Shenyang Electric Machine Manufacturing Co., Ltd.
Shenyang Electric Machine Manufacturing Co., Ltd. is one of the most professional dgam bo subseries motor manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy high quality dgam bo subseries motor at competitive price from our factory. If you have any enquiry about quotation, please feel free to email us.
Address: No.24, Kaifa 24th Road, Shenyang, Liaoning Province, China, 110142
E-mail: cndk@cndk-cn.com
WebSite: https://www.cndk-en.com/